{"id":2064,"date":"2026-01-13T11:39:44","date_gmt":"2026-01-13T10:39:44","guid":{"rendered":"https:\/\/cf-systems.de\/produkt\/cf-nano%e2%82%82\/"},"modified":"2026-08-21T12:50:07","modified_gmt":"2026-08-21T10:50:07","slug":"cf-nano2","status":"publish","type":"produkt","link":"https:\/\/cf-systems.de\/en\/product\/cf-nano2\/","title":{"rendered":"[CF] NANO\u2082"},"content":{"rendered":"\n\t<section id=\"intro-block_bcf185dd1961165c013c2a2c2a4fa883\" class=\"intro\" style=\"  \">\n\n\t\t\n\t\t\t\t<div class=\"intro-three\">\n                    <div class=\"container\">\n                        <div class=\"intro-three-wrapper\">\n                            <div class=\"intro-three-item\">\n\n                                <p><img decoding=\"async\" class=\"alignnone wp-image-800 size-medium\" src=\"https:\/\/cf-systems.de\/wp-content\/uploads\/images\/CF-Nano2-2025-petrol-web-300x62.png\" alt=\"CF Nano2 2025\" width=\"300\" height=\"62\" srcset=\"https:\/\/cf-systems.de\/wp-content\/uploads\/images\/CF-Nano2-2025-petrol-web-300x62.png 300w, https:\/\/cf-systems.de\/wp-content\/uploads\/images\/CF-Nano2-2025-petrol-web.png 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<h1>Compact CO<sub>2<\/sub> systems for small cooling capacities<\/h1>\n<p>The [CF] NANO<sub>2<\/sub> series was designed for applications with low cooling capacity \u2013 ideal for gastronomy, hotels, and retail.<\/p>\n<ul>\n<li>Redundancy through compound design<\/li>\n<li>Flexible Installation \u2013 lndoor &#038; Outdoor<\/li>\n<li>Designed for minimal partial loads<\/li>\n<li>Carel, Danfoss, or Wurm control technology<\/li>\n<li>Active oil management<\/li>\n<li>Compact construction<\/li>\n<li>Suitable for cold rooms under 1.5 kW<\/li>\n<li>Maintenance-friendly<\/li>\n<\/ul>\n\n                            <\/div>\n                            <!-- \/.intro-three-item -->\n\n\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"intro-three-img-wrapper\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/cf-systems.de\/wp-content\/uploads\/images\/CF-NANO\u2082-cf-systems-1024x768.jpg\" alt=\"CF NANO\u2082 CO2 system for gastronomy and hotels CF SYSTEMS\" class=\"intro-three-img\">\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<!-- \/.intro-three-img-wrapper -->\n\n\t\t\t\t\t\t\t\n                        <\/div>\n                        <!-- \/.intro-three-wrapper -->\n                    <\/div>\n                    <!-- \/.container -->\n                <\/div>\n                <!-- \/.intro-three -->\n\n\t\t\t\t\t\n\t<\/section> <!--  .intro -->\n\n\n\n\n\t<section id=\"section-faq-block_c9626c5f75dd0aef204a3f99f577531c\" class=\"section-faq\" style=\"  \">\n\t\t<div class=\"container\">\n\t\t\t<div class=\"section-faq-wrapper\">\n\n\t\t\t\t<h2>Why [CF] NANO\u2082?<\/h2>\n\t\t\t\t\t<div id=\"accordion-wrapper\" class=\"accordion-wrapper\">\n\n\t\t\t\t\t\t<div class=\"accordion\"><p class=\"accordiion-title\">The robust system for minimal partial load is often underestimated<\/p><!-- \/.accordiion-title --><i class=\"icon-cf-oem-arrow-down\"><\/i><\/div><!-- accordion --><div class=\"accordion-item\"><p>When designing refrigeration systems, the focus is often on maximum cooling capacity \u2013 although this is only actually needed for a few hours a year. Most of the time, the system operates in partial load, which is often neglected in planning and poses technical challenges, especially for CO<sub>\u2082<\/sub> systems in the lower performance range. <\/p>\n<\/div><div class=\"accordion\"><p class=\"accordiion-title\">Planning for minimal cooling load is crucial<\/p><!-- \/.accordiion-title --><i class=\"icon-cf-oem-arrow-down\"><\/i><\/div><!-- accordion --><div class=\"accordion-item\"><p>Therefore, the following aspects should be considered already in the project planning phase:<\/p>\n<ul>\n<li>Cold room operation in partial load: Which cold rooms could run individually?<\/li>\n<li>Real minimum cooling load: Lowest expected utilization.<\/li>\n<li>Low-load periods: Times with low demand (e.g., at night, outside of use).<\/li>\n<li>Influence of outside temperature: Higher partial load capacity at cool outside temperatures.<\/li>\n<\/ul>\n<\/div><div class=\"accordion\"><p class=\"accordiion-title\">System design makes the difference<\/p><!-- \/.accordiion-title --><i class=\"icon-cf-oem-arrow-down\"><\/i><\/div><!-- accordion --><div class=\"accordion-item\"><p>In the lower performance range, partial load is often not considered \u2013 typically, plug &#038; play units with single-compressor design are used here. However, due to their design, these are only suitable to a limited extent for the challenges of partial load operation. The compound design of the [CF] NANO<sub>2<\/sub>, on the other hand, enables:  <\/p>\n<ul>\n<li>a significantly lower partial load with the same maximum capacity<\/li>\n<li>increased operational reliability through multiple compressors<\/li>\n<\/ul>\n<\/div><div class=\"accordion\"><p class=\"accordiion-title\">Active oil management for maximum safety<\/p><!-- \/.accordiion-title --><i class=\"icon-cf-oem-arrow-down\"><\/i><\/div><!-- accordion --><div class=\"accordion-item\"><ul>\n<li>If the minimum partial load is not safely dissipated, the compressors cycle. The consequences: high wear, oil carry-over, and oil deficiency \u2013 a common cause of failure in plug &#038; play units in systems with low partial load. <\/li>\n<li>The [CF] NANO\u2082 protects itself: Active oil management detects oil deficiency early, automatically switches off the compressor, and ensures optimal oil filling \u2013 for continuous operational reliability.<\/li>\n<\/ul>\n<\/div>\t\t\t\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<!--  .slider -->\n\n\t\t\t\t\t\t\t\t\n\t\t\t<\/div>\n\t\t\t<!-- \/.section-faq-wrapper -->\n\t\t<\/div>\n\t\t<!-- \/.container -->\n\t<\/section> <!--  .section-faq -->\n\n\n\n\n\t<section id=\"featured-blocks-block_57cca5e2c9c7753234f21523ac9691ed\" class=\"featured-blocks\" style=\"  \">\n\t\t<div class=\"container container--narrow\">\n\t\t\t<div class=\"flex-row\">\n\t\t\t\t<div class=\"col-6@md\">\n\t\t\t\t\t<div class=\"featured-blocks-item featured-blocks-item--one\">\n\n\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/cf-systems.de\/wp-content\/uploads\/images\/block1.png\" alt=\"Icon Innen Aussen - CF Systems\" \/><p>Installation through <br \/>\r\nstandard door dimensions<\/p>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<!-- \/.featured-blocks-item -->\n\t\t\t\t<\/div>\n\t\t\t\t<!-- \/.col-6@md -->\n\n\t\t\t\t\n\t\t\t\t\t<div class=\"col-6@md\">\n\t\t\t\t\t\t<div class=\"featured-blocks-item featured-blocks-item--two\">\n\n\t\t\t\t\t\t\t<p>Performance range <br \/>\r\nfrom<\/p><p class=\"big\"><span>3\u202610kW*<\/span><img decoding=\"async\" src=\"https:\/\/cf-systems.de\/wp-content\/uploads\/images\/block1-icon.svg\" alt=\"Icon Temperatur - CF Systems\" \/><\/p>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!-- \/.featured-blocks-item -->\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<!-- \/.col-6@md -->\n\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t<!-- \/.flex-row -->\n\t\t<\/div>\n\t\t<!-- \/.container -->\n\t<\/section>\n\t<!--  .featured-blocks -->\n\n\n\n\n\t\t<section id=\"content-block_27876b0fbc907ba4aef6c4c5a5225142\" class=\"content\" style=\"  \">\n\t\t\t<div class=\"container\">\n\t\t\t\t<div class=\"flex-row\">\n\n\t\t\t\t\t\n\t\t\t\t\t\t<div class=\"col-12\">\n\n\t\t\t\t\t\t\t<h2>Technical data<\/h2>\n\n<table id=\"tablepress-12\" class=\"tablepress tablepress-id-12\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\"><strong>Type<\/strong><\/th><th class=\"column-2\"><strong>[CF] NANO\u2082[2&#215;0] 2&#215;0[7]X[Do]1V14<\/strong><\/th><th class=\"column-3\"><strong>[CF] NANO\u2082[2&#215;0] 3&#215;0[13]X[Do]1V14<\/strong><\/th><th class=\"column-4\"><strong>[CF] NANO\u2082[2&#215;0] 5&#215;0[18]X[Do]1V14<\/strong><\/th><th class=\"column-5\"><strong>[CF] NANO\u2082[3&#215;0] 4&#215;0[11]X[Do]1V14<\/strong><\/th><th class=\"column-6\"><strong>[CF] NANO\u2082[3&#215;0] 5&#215;0[21]X[Do]1V14<\/strong><\/th><th class=\"column-7\"><strong>[CF] NANO\u2082[3&#215;0] 7&#215;0[25]X[Do]1V14<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\"><strong>Order No. Carel<\/strong><\/td><td class=\"column-2\">182-2110<\/td><td class=\"column-3\">182-2111<\/td><td class=\"column-4\">182-2112<\/td><td class=\"column-5\">182-2120<\/td><td class=\"column-6\">182-2121<\/td><td class=\"column-7\">182-2122<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\"><strong>Order No. Danfoss<\/strong><\/td><td class=\"column-2\">182-2130<\/td><td class=\"column-3\">182-2131<\/td><td class=\"column-4\">182-2132<\/td><td class=\"column-5\">182-2140<\/td><td class=\"column-6\">182-2141<\/td><td class=\"column-7\">182-2142<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\"><strong>Min. capacyity<\/strong><\/td><td class=\"column-2\">1.40 kW<\/td><td class=\"column-3\">1.84 kW<\/td><td class=\"column-4\">3.31 kW<\/td><td class=\"column-5\">1.40 kW<\/td><td class=\"column-6\">2.49 kW<\/td><td class=\"column-7\">3.31 kW<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\"><strong>Max. capacity<\/strong><\/td><td class=\"column-2\">2.94 kW<\/td><td class=\"column-3\">4.56 kW<\/td><td class=\"column-4\">6.96 kW<\/td><td class=\"column-5\">5.07 kW<\/td><td class=\"column-6\">7.73 kW<\/td><td class=\"column-7\">10.09 kW<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\"><strong>Gas cooler capacity<\/strong><\/td><td class=\"column-2\">5.03 kW<\/td><td class=\"column-3\">7.95 kW<\/td><td class=\"column-4\">11.96 kW<\/td><td class=\"column-5\">8.57 kW<\/td><td class=\"column-6\">13.31 kW<\/td><td class=\"column-7\">17.13 kW<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\"><strong>Number of compressors<\/strong><\/td><td class=\"column-2\">2<\/td><td class=\"column-3\">2<\/td><td class=\"column-4\">2<\/td><td class=\"column-5\">3<\/td><td class=\"column-6\">3<\/td><td class=\"column-7\">3<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\"><strong>receiver volume<\/strong><\/td><td class=\"column-2\">14 l<\/td><td class=\"column-3\">14 l<\/td><td class=\"column-4\">14 l<\/td><td class=\"column-5\">14 l<\/td><td class=\"column-6\">14 l<\/td><td class=\"column-7\">14 l<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\"><strong>discharge line connection<\/strong><\/td><td class=\"column-2\">\u215c&#8221;<\/td><td class=\"column-3\">\u215c&#8221;<\/td><td class=\"column-4\">\u215c&#8221;<\/td><td class=\"column-5\">\u00be&#8221;<\/td><td class=\"column-6\">\u00be&#8221;<\/td><td class=\"column-7\">\u00be&#8221;<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\"><strong>Gas cooler return line<\/strong><\/td><td class=\"column-2\">\u215c&#8221;<\/td><td class=\"column-3\">\u215c&#8221;<\/td><td class=\"column-4\">\u215c&#8221;<\/td><td class=\"column-5\">\u00be&#8221;<\/td><td class=\"column-6\">\u00be&#8221;<\/td><td class=\"column-7\">\u00be&#8221;<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\"><strong>Liquid line<\/strong><\/td><td class=\"column-2\">\u215c&#8221;<\/td><td class=\"column-3\">\u215c&#8221;<\/td><td class=\"column-4\">\u215c&#8221;<\/td><td class=\"column-5\">\u00be&#8221;<\/td><td class=\"column-6\">\u00be&#8221;<\/td><td class=\"column-7\">\u00be&#8221;<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\"><strong>Suction line<\/strong><\/td><td class=\"column-2\">\u215c&#8221;<\/td><td class=\"column-3\">\u215c&#8221;<\/td><td class=\"column-4\">\u215c&#8221;<\/td><td class=\"column-5\">\u00be&#8221;<\/td><td class=\"column-6\">\u00be&#8221;<\/td><td class=\"column-7\">\u00be&#8221;<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\"><strong>PS HP<\/strong><\/td><td class=\"column-2\">120 bar<\/td><td class=\"column-3\">120 bar<\/td><td class=\"column-4\">120 bar<\/td><td class=\"column-5\">120 bar<\/td><td class=\"column-6\">120 bar<\/td><td class=\"column-7\">120 bar<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\"><strong>PS MP<\/strong><\/td><td class=\"column-2\">90 bar<\/td><td class=\"column-3\">90 bar<\/td><td class=\"column-4\">90 bar<\/td><td class=\"column-5\">90 bar<\/td><td class=\"column-6\">90 bar<\/td><td class=\"column-7\">90 bar<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\"><strong>PS NP<\/strong><\/td><td class=\"column-2\">90 bar<\/td><td class=\"column-3\">90 bar<\/td><td class=\"column-4\">90 bar<\/td><td class=\"column-5\">90 bar<\/td><td class=\"column-6\">90 bar<\/td><td class=\"column-7\">90 bar<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\"><strong>Sound pressure level at 10 m<\/strong><\/td><td class=\"column-2\">33.5 dB(A)<\/td><td class=\"column-3\">34.5 dB(A)<\/td><td class=\"column-4\">36 dB(A)<\/td><td class=\"column-5\">35.6 dB(A)<\/td><td class=\"column-6\">36.8 dB(A)<\/td><td class=\"column-7\">37.8 dB(A)<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\"><strong>Max. operating current<\/strong><\/td><td class=\"column-2\">6.3 A<\/td><td class=\"column-3\">8.3 A<\/td><td class=\"column-4\">14.3 A<\/td><td class=\"column-5\">10.7 A<\/td><td class=\"column-6\">14.8 A<\/td><td class=\"column-7\">20.3 A<\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\"><strong>weight<\/strong><\/td><td class=\"column-2\">354 kg<\/td><td class=\"column-3\">360 kg<\/td><td class=\"column-4\">363 kg<\/td><td class=\"column-5\">404 kg<\/td><td class=\"column-6\">412 kg<\/td><td class=\"column-7\">415 kg<\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td><td class=\"column-4\"><\/td><td class=\"column-5\"><\/td><td class=\"column-6\"><\/td><td class=\"column-7\"><\/td>\n<\/tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\"><strong>Gas cooler type<\/strong><\/td><td class=\"column-2\"><strong>GW30E213AF001<\/strong><\/td><td class=\"column-3\"><strong>GW30E213AF001<\/strong><\/td><td class=\"column-4\"><strong>GP45C114BF001<\/strong><\/td><td class=\"column-5\"><strong>GW30E213AF001<\/strong><\/td><td class=\"column-6\"><strong>GP45C114BF001<\/strong><\/td><td class=\"column-7\"><strong>GP45C114BF001<\/strong><\/td>\n<\/tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\"><strong>Order No..<\/strong><\/td><td class=\"column-2\">185-1088<\/td><td class=\"column-3\">185-1088<\/td><td class=\"column-4\">185-1089<\/td><td class=\"column-5\">185-1088<\/td><td class=\"column-6\">185-1089<\/td><td class=\"column-7\">185-1089<\/td>\n<\/tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\"><strong>Air discharge direction<\/strong><\/td><td class=\"column-2\">horizontal<\/td><td class=\"column-3\">horizontal<\/td><td class=\"column-4\">horizontal &amp; vertical<\/td><td class=\"column-5\">horizontal<\/td><td class=\"column-6\">horizontal &amp; vertical<\/td><td class=\"column-7\">horizontal &amp; vertical<\/td>\n<\/tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\"><strong>Sound pressure level at 10 m<\/strong><\/td><td class=\"column-2\">40 dB(A)<\/td><td class=\"column-3\">40 dB(A)<\/td><td class=\"column-4\">42 dB(A)<\/td><td class=\"column-5\">40 dB(A)<\/td><td class=\"column-6\">42 dB(A)<\/td><td class=\"column-7\">42 dB(A)<\/td>\n<\/tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\"><strong>Connections (inch)<\/strong><\/td><td class=\"column-2\">\u00d8 \u00be K65<\/td><td class=\"column-3\">\u00d8 \u00be K65<\/td><td class=\"column-4\">\u00d8 \u00be K65<\/td><td class=\"column-5\">\u00d8 \u00be K65<\/td><td class=\"column-6\">\u00d8 \u00be K65<\/td><td class=\"column-7\">\u00d8 \u00be K65<\/td>\n<\/tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\"><strong>Length x width x height<\/strong><\/td><td class=\"column-2\">1152 \u00d7 316 \u00d7 533<\/td><td class=\"column-3\">1152 \u00d7 316 \u00d7 533<\/td><td class=\"column-4\">981 \u00d7 646 \u00d7 753<\/td><td class=\"column-5\">1152 \u00d7 316 \u00d7 533<\/td><td class=\"column-6\">981 \u00d7 646 \u00d7 753<\/td><td class=\"column-7\">981 \u00d7 646 \u00d7 753<\/td>\n<\/tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\"><strong>Weight<\/strong><\/td><td class=\"column-2\">28 kg<\/td><td class=\"column-3\">28 kg<\/td><td class=\"column-4\">63 kg<\/td><td class=\"column-5\">28 kg<\/td><td class=\"column-6\">63 kg<\/td><td class=\"column-7\">63 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-12 from cache -->\n<p>* The capacity is calculated at: t0 -10 \u00b0C, GKaus 38 \u00b0C and 93 bar<br \/>\n** incl. control cabinet<br \/>\n***without pipe outlets <\/p>\n<p>&nbsp;<\/p>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!--  .col-12 -->\n\n\t\t\t\t\t\n\t\t\t\t<\/div>\n\t\t\t\t<!--  .flex-row -->\n\t\t\t<\/div> <!--  .container -->\n\t\t<\/section>\n\t\t<!--  .content -->\n\n\t\n\n\n\t\t<section id=\"product-info-block_df6b2da86fc34f2022efed9be5dc8457\" class=\"product-info\" style=\"  \">\n\t\t\t<div class=\"container\">\n\n\t\t\t\t\n\t\t\t\t\t<div class=\"flex-row\">\n\t\t\t\t\t\t<div class=\"col-5@md\">\n\t\t\t\t\t\t\t<div class=\"product-info-item\">\n\n\t\t\t\t\t\t\t\t<h2>Scope of delivery<\/h2>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<!-- \/.product-info-item -->\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!-- \/.col-5@md -->\n\t\t\t\t\t\t<div class=\"col-7@md\">\n\t\t\t\t\t\t\t<div class=\"product-info-item\">\n\n\t\t\t\t\t\t\t\t<div class=\"product-info-item-content\"><ul><span data-mce-type=\"bookmark\" style=\"display: inline-block; width: 0px; overflow: hidden; line-height: 0;\" class=\"mce_SELRES_start\"><\/span><\/p>\n<li>2 to 3 MT compressors (transcritical)<\/li>\n<li>Capacity control of the MT lead compressor via VFD<\/li>\n<li>Active oil management<\/li>\n<li>Receiver (14 l)<\/li>\n<li>Service and shut-off valves on all service-relevant pipe sections<\/li>\n<li>Pressure and temperature sensors matched to the respective control manufacturer<\/li>\n<li>high-quality insulation with Armacell AF<\/li>\n<li>All pipe outlets (CuFe<sub>2<\/sub>P) are routed to the rear.<\/li>\n<li>Pressure-resistant design (HD= PS120, all others PS90)<\/li>\n<li>fully welded base plate including vibration dampers<\/li>\n<li>Control cabinet, assembled, wired, and pre-programmed<\/li>\n<\/ul>\n<\/div><a href=\"javascript:;\" class=\"btn btn-primary read-more\" data-text-read-more=\"More content\" data-text-read-less=\"Less content\"><span>More content<\/span><svg width=\"9\" height=\"11\" viewBox=\"0 0 9 11\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M4.5 0.499999L4.5 10.5M4.5 10.5L8.5 6.75M4.5 10.5L0.5 6.75\" stroke=\"white\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\/><\/svg><\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<!-- \/.product-info-item -->\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!-- \/.col-7@md -->\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<!-- \/.flex-row -->\n\n\t\t\t\t\n\t\t\t\t\t<div class=\"flex-row\">\n\t\t\t\t\t\t<div class=\"col-5@md\">\n\t\t\t\t\t\t\t<div class=\"product-info-item\">\n\n\t\t\t\t\t\t\t\t<h2>Options<\/h2>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<!-- \/.product-info-item -->\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!-- \/.col-5@md -->\n\t\t\t\t\t\t<div class=\"col-7@md\">\n\t\t\t\t\t\t\t<div class=\"product-info-item\">\n\n\t\t\t\t\t\t\t\t<div class=\"product-info-item-content\"><ul><span data-mce-type=\"bookmark\" style=\"display: inline-block; width: 0px; overflow: hidden; line-height: 0;\" class=\"mce_SELRES_start\"><\/span><\/p>\n<li>Housing for indoor and outdoor installation without sound insulation, supplied loose<\/li>\n<li>Heat recovery with 3-way valve, supplied loose<\/li>\n<li>Filter drier, supplied loose<\/li>\n<li>Gas cooler, supplied loose<\/li>\n<\/ul>\n<\/div><a href=\"javascript:;\" class=\"btn btn-primary read-more\" data-text-read-more=\"More content\" data-text-read-less=\"Less content\"><span>More content<\/span><svg width=\"9\" height=\"11\" viewBox=\"0 0 9 11\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M4.5 0.499999L4.5 10.5M4.5 10.5L8.5 6.75M4.5 10.5L0.5 6.75\" stroke=\"white\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\/><\/svg><\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<!-- \/.product-info-item -->\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!-- \/.col-7@md -->\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<!-- \/.flex-row -->\n\n\t\t\t\t\n\t\t\t\t\t<div class=\"flex-row\">\n\t\t\t\t\t\t<div class=\"col-5@md\">\n\t\t\t\t\t\t\t<div class=\"product-info-item\">\n\n\t\t\t\t\t\t\t\t<h2>Control &#038; control cabinet<\/h2>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<!-- \/.product-info-item -->\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!-- \/.col-5@md -->\n\t\t\t\t\t\t<div class=\"col-7@md\">\n\t\t\t\t\t\t\t<div class=\"product-info-item\">\n\n\t\t\t\t\t\t\t\t<div class=\"product-info-item-content\"><ul>\n<li>Carel \u03bcRack CO<sub>2<\/sub>, Danfoss AK-PC 572A, Wurm DCO<sub>2<\/sub>-BL (on request)<\/li>\n<li>Main switch<\/li>\n<li>Control transformer<\/li>\n<li>Power supply for closing the HP and MP valves in the event of power failure<\/li>\n<\/ul>\n<\/div><a href=\"javascript:;\" class=\"btn btn-primary read-more\" data-text-read-more=\"More content\" data-text-read-less=\"Less content\"><span>More content<\/span><svg width=\"9\" height=\"11\" viewBox=\"0 0 9 11\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M4.5 0.499999L4.5 10.5M4.5 10.5L8.5 6.75M4.5 10.5L0.5 6.75\" stroke=\"white\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\/><\/svg><\/a>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<!-- \/.product-info-item -->\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!-- \/.col-7@md -->\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<!-- \/.flex-row -->\n\n\t\t\t\t\n\t\t\t\t\t<div class=\"flex-row\">\n\t\t\t\t\t\t<div class=\"col-5@md\">\n\t\t\t\t\t\t\t<div class=\"product-info-item\">\n\n\t\t\t\t\t\t\t\t<h2>Dimensional drawing<\/h2>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<!-- \/.product-info-item -->\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!-- \/.col-5@md -->\n\t\t\t\t\t\t<div class=\"col-7@md\">\n\t\t\t\t\t\t\t<div class=\"product-info-item\">\n\n\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/cf-systems.de\/wp-content\/uploads\/images\/CF-NANO\u2082-Masszeichnung-cf-systems.png\" alt=\"CF NANO\u2082 Ma\u00dfzeichnung CF SYSTEMS\" \/>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<!-- \/.product-info-item -->\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<!-- \/.col-7@md -->\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<!-- \/.flex-row -->\n\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t<!-- \/.container -->\n\t\t<\/section>\n\t\t<!--  .product-info -->\n\n\t","protected":false},"excerpt":{"rendered":"<p>[CF] NANO<sub>2<\/sub> was designed for applications with low cooling capacity \u2013 ideal for gastronomy, hotels, and retail. <a href=\"https:\/\/cf-systems.de\/en\/product\/cf-nano2\/\" class=\"more-link\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"featured_media":2068,"template":"","class_list":["post-2064","produkt","type-produkt","status-publish","has-post-thumbnail","hentry","odd"],"acf":[],"_links":{"self":[{"href":"https:\/\/cf-systems.de\/en\/wp-json\/wp\/v2\/produkt\/2064","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cf-systems.de\/en\/wp-json\/wp\/v2\/produkt"}],"about":[{"href":"https:\/\/cf-systems.de\/en\/wp-json\/wp\/v2\/types\/produkt"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cf-systems.de\/en\/wp-json\/wp\/v2\/media\/2068"}],"wp:attachment":[{"href":"https:\/\/cf-systems.de\/en\/wp-json\/wp\/v2\/media?parent=2064"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}