CO2RE - cf-systems

CO₂ Compound System in Modular Design

Designed for larger capacities, for example in food retail, industry or logistics.

  • Flexible Installation – lndoor & Outdoor
  • Quiet Operation through various Soundproofing Options
  • Modular Construction
  • Easy to Install
  • Maintenance-friendly
  • Wide Performance Range
CO2RE [CF] SYSTEMS CO₂ compound system for food retail, industry or logistics CF SYSTEMS

Technical data

Frame size2 x 23 x 34 x 45 x 46 x 4
Number of MT compressors23456
Number of LT compressorsmax. 2max. 3max. 4max. 4max. 4
Length in mm **2,8803,3304,0904,5404,990
Width in mm800800800800800
Height in mm ***1,9601,9601,9601,9601,960

* Performance calculation based on evaporation temperatures:
–8 °C MT, –30 °C LT and 37 °C gas cooler outlet temperature

** incl. control cabinet

***without pipe outlets

More content

Capacity range

CF Systems Leistungsbereich Co2re CF SYSTEMS

Scope of delivery

  • 2 to 6 MT compressors (transcritical) and up to 4 LT compressors (subcritical)
  • Capacity control for the MT lead compressor
  • Active oil management
  • Receiver (83 to 285 l) with minimum level indicator
  • Flash gas heat exchanger
  • LT suction gas superheater
  • Mechanical filters in oil line, before the HP valve, in liquid line and in LT suction line
  • Filter dryer in the MT suction line
  • Service and shut-off valves on all service-relevant components and pipe sections
  • Pressure gauges for each pressure stage
  • Pressure and temperature sensors matched to the desired control system brand
  • High-end insulation executed in Armacell AF
  • All pipe outlets (CuFe2P) are routed upwards.
  • Safety valves mounted on valve panel, loose for on-site installation
  • Fully welded heavy-duty frame incl. vibration dampers
More content

Options

  • Capacity control
    • MT lead compressor: Standard or pulse width modulated
    • MT lag compressor: capacity control 50/100%
    • LT lead compressor: frequency inverter
  • Heat recovery with 3-way valve, ball valves and insulation of discharge line, oil separator and heat exchanger, optional gas cooler bypass
  • Redundant HP and MP valves
  • Standstill cooling, R290
  • Bypass of the filter dryer in MT suction line
  • Mounted LT desuperheater or external LT desuperheater with 3-way valve and muffler
  • Liquid ejector incl. liquid separator
  • Active liquid subcooling
  • MT and LT hot gas injection
  • MT liquid injection
  • Low pressure switch
  • Pre-wiring
  • Control cabinet, mounted or loose
  • Air spring elements
  • Housing for indoor and outdoor installation
More content

Control & control cabinet

  • Main switch
  • Active control cabinet ventilation
  • Control cabinet lighting and socket
  • Power supply for closing the HP and MP valves in the event of power failure
  • Shared energy metering (optional)
  • Control transformer
  • Surge protection (optional)
  • Monitoring system (optional)
  • Control technology optionally CAREL, Danfoss, WURM
More content

Dimensional drawing

CO₂RE Masszeichnung CF SYSTEMS