CO₂ compound system with minimal footprint
Designed, among other applications, for petrol stations and small retailers with a store size of up to 1,000 m².
- Euro pallet-sized footprint (including control cabinet)
- Flexible Installation – lndoor & Outdoor
- Quiet Operation through various Soundproofing Options
- Compact construction
- Easy to Install
- Maintenance-friendly

Installation through
standard door dimensions
Performance range
from
5…40 kW*
3…10kW*
Technical data
| FRAME SIZE | 2 x 1 |
|---|---|
| Number of MT compressors | 1 – 2 |
| Number of LT compressors | max. 1 |
| Length in mm ** | 1,200 |
| Width in mm | 800 |
| Height in mm *** | 1,960 |
* Performance calculation based on evaporation temperatures:
–8 °C MT, –30 °C LT and 37 °C gas cooler outlet temperature
** incl. control cabinet
***without pipe outlets
Capacity range
Scope of delivery
- 1 to 2 MT compressors (transcritical) and max. 1 LT compressor (subcritical)
- Capacity control for the MT lead compressor
- Active oil management
- Receiver (60 l) with minimum level indicator
- Mechanical filters in the oil line and upstream of the high-pressure valve
- Filter drier in the MT suction line
- Service and shut-off valves on all service-relevant components and pipe sections
- Pressure gauges for each pressure stage
- Pressure and temperature sensors matched to the desired control system brand
- High-end insulation executed in Armacell AF
- All piping outlets (CuFe2P) are routed upwards
- Safety valves mounted on valve panel, loose for on-site installation
- Fully welded heavy-duty frame incl. vibration dampers
Options
- Capacity control
- MT lead compressor: frequency inverter (standard) or pulse-width modulated
- MT lag compressor: capacity control 50/100%
- LT lead compressor: frequency inverter
- Heat recovery with 3-way valve, ball valves and insulation of the discharge line, oil separator and heat exchanger
- MT hot-gas liquid injection
- MT liquid injection
- Low pressure switch
- Pre-wiring
- Control cabinet, assembled or supplied loose for on-site installation
- Air spring elements
- Enclosure for indoor and outdoor installation
Control & control cabinet
- Control technology optionally CAREL, Danfoss or WURM
- Main switch
- Active control cabinet ventilation
- Control transformer
- Power supply for closing the HP and MP valves in the event of power failure